{"product_id":"rx-schuco-compressor-nebulizer-model-s5000-2","title":"Rx Schuco Compressor Nebulizer Model S5000","description":"Schuco S5000 Nebulizer  The Schuco S5000 Nebulizer Quiet operation, less than 60 dBA. It is compact and lightweight, just 3-1\/2 lbs. Easy to use and clean. Convenient cord storage compartment. Substantial compressor pressure, 35-45 psig. High compressor operating flow rate, 7-11 lpm. Therapeutic particle size, 0.5 µm-5µm. AC operation, 120V 60 Hz. UL classified with a 5-year limited warranty. - CAUTIONS\/WARNINGS:Read all warnings before using your nebulizer.\u003cbr\u003e\nCaution: U.S. Federal Law restricts this device to sale by or on the order of a physician. Use only when prescribed by a physician and with the prescribed medication.\u003cbr\u003e\nRead all warnings and users manual before use. Use the product only for its intended uses as described in the users manual. Improper use can result in serious or fatal illness\/injury  improper treatment or property damage.\u003cbr\u003e\nUse only with nebulizers  tubing and accessories approved for this device. Other compressors and tubing may produce incorrect flow  resulting in improper dosage. Use with other compressors  tubing and accessories should be reviewed with your healthcare professional.\u003cbr\u003e\nCaution\u003cbr\u003e\nThis appliance is not for unattended use.\u003cbr\u003e\nNebulizer compressor safety precautions\u003cbr\u003e\n1. Do not place or store the product where it can fall or be knocked into bathtub  sink  water  or other liquid. Do not place or drop into any liquid. Do not use while bathing.\u003cbr\u003e\n2. Do not reach for a product that has fallen into water or other liquid. Unplug immediately.\u003cbr\u003e\n3. Always unplug immediately after using.\u003cbr\u003e\nWarning\u003cbr\u003e\nTo reduce the risk of serious or fatal injury from electrocution  fire burns and to reduce the risk of damage or malfunction of the unit:\u003cbr\u003e\n1. Before use  check the serial number label on the bottom of the compressor to ensure that the voltage and current indicated on the unit correspond with the voltage and current available.\u003cbr\u003e\n2. Never operate this product if it:\u003cbr\u003e\n Has a damaged cord or plug\u003cbr\u003e\n Is not working properly\u003cbr\u003e\n Has been dropped or damaged\u003cbr\u003e\n Has been exposed to any liquids inside the case.\u003cbr\u003e\n3. Keep all electrical cords away from heated surfaces. Do not overload wall outlets or use extension cords.\u003cbr\u003e\n4. Do not operate where oxygen is being administered in a closed environment such as an oxygen tent.\u003cbr\u003e\n5. Never drop or insert any object into any opening.\u003cbr\u003e\n6. Do not open or disassemble the compressor. Refer all servicing to Allied Health-care Products Inc. authorized service center.\u003cbr\u003e\n7. Never spray liquid onto the compressor housing. Fluid could cause damage to the electrical and compressor parts and could lead to a malfunction. In the event that fluids enter the unit  return the product to allied or an authorized service center for examination and repair.\u003cbr\u003e\n8. Do not use the nebulizer while operating a vehicle\u003cbr\u003e\n9. EMI\/RFI recommendations \u003cbr\u003e\na. Do not turn on or use hand-held personal electronic communication devices such as cellular phones  walkie-talkies and CB radios while the compressor is turned on.\u003cbr\u003e\nb. Be aware of any nearby transmitters (radio  television  microwave  etc.) and avoid operating the compressor close to any of these transmitters.\u003cbr\u003e\nc. Turn off the power if the compressor is not going to be used for any length of time.\u003cbr\u003e\nd. Be aware that adding accessories or components or modifying the compressor may make it more susceptible to EMI\/RFI.\u003cbr\u003e\nWarning\u003cbr\u003e\n1. Tubing and accessories are for single patient use only. Do not share your tubing and accessories with other patients.\u003cbr\u003e\n2. To reduce the risk of increased bacterial growth  infection  illness or injury from contamination  thoroughly clean and dry all parts of tubing and accessories and thoroughly dry any moisture or condensation in the tubing at the end of every treatment  following the instructions below.\u003cbr\u003e\n3. Cleaning the nebulizer unit after each treatment is not enough. The tubing and accessories must also be regularly sterilized and disinfected between treatments to prevent serious or fatal illness caused by contamination.\u003cbr\u003e\n4. Never use tubing with clogged nozzle. If the nozzle is clogged  the aerosol mist will be reduced  altered or stopped  which will diminish or eliminate the effectiveness of the treatment. If clogging occurs  replace with the same model.\u003cbr\u003e\n5. Close supervision is necessary when this product is used by or near children and physically or mentally impaired persons. Never use when sleeping or drowsy.\u003cbr\u003e\n6. This product contains small parts that may present a choking hazard to small children. The tubing also presents a strangulation hazard.\u003cbr\u003e\n7. Children under the age of 3 any patient who is unable to use a mouthpiece properly under supervision should use a mask.\u003cbr\u003e\n8. Before use  check tubing and accessories for proper assembly. All parts should be seated firmly in place. Use of improperly assemble tubing and accessories could diminish or prevent adequate delivery of medication and the effectiveness of the treatment.\u003cbr\u003e - DIRECTIONS:Getting Started\u003cbr\u003e\n1. Check to ensure the following components of the nebulizer are enclosed:\u003cbr\u003e\n Compressor unit\u003cbr\u003e\n Tubing and accessories\u003cbr\u003e\nIf you did not receive the components listed  please contact the dealer where you purchased your nebulizer.\u003cbr\u003e\n2. It is always a good idea to keep extra tubing and accessories and an extra air filter on hand at all times. You may need them if parts become lost  damaged  or soiled.\u003cbr\u003e\nSetting up nebulizer compressor and nebulizer accessories\u003cbr\u003e\n1. Wash hands with soap and warm water and dry completely with a clean towel.\u003cbr\u003e\n2. Place the compressor on a clean  dust-free  stable and flat surface. Check the filter monthly or every 10-12 treatments and replace if dirty  clogged  or wet to ensure proper operation.\u003cbr\u003e\nNote: Tubing and accessories are not sterile from package.\u003cbr\u003e\n3. Make sure tubing and accessories have been cleaned or disinfected before first use and after last daily treatment. Refer to the cleaning and disinfecting tubing and accessories section.\u003cbr\u003e\n4. Remove the nebulizer cap by twisting counter clockwise until it stops and lifts up.\u003cbr\u003e\n5. Fill nebulizer cup using eyedropper or syringe with prescribed medication  do not fill more than 8 ml per treatment.\u003cbr\u003e\n6. Close the nebulizer cap and turn clockwise until it is tightened\u003cbr\u003e\n7. If using the mask press it directly into the nebulizer cap.\u003cbr\u003e\n8. If using the mouthpiece  attach it firmly into the nebulizer cap. The cap is designed to fit tightly.\u003cbr\u003e\n9. Press one end of the tubing firmly onto to the air outlet on the side of the compressor unit. It is important that the tubing be pushed firmly all the way onto the air outlet of the compressor unit. The tubing is designed to fit tightly.\u003cbr\u003e\n10. Firmly press the other end of the tubing onto the bottom of the nebulizer cup.\u003cbr\u003e\nOperating the compressor nebulizer\u003cbr\u003e\n1. Take the power cord out of the storage cavity and plug into an electrical outlet.\u003cbr\u003e\n2. Locate the power switch on the front of the unit  and switch it to the “on” position as shown below.\u003cbr\u003e\n3. Check for moisture leakage near the connections.\u003cbr\u003e\n4. There are 3 ways to administer medication with this nebulizer (A) Hold the air intake near the nose.(B) If using a mask put the mask on the face. (C) If using a mouthpiece  hold it in the mouth.\u003cbr\u003e\n5. Inhale the liquid nebulizer medication\u003cbr\u003e\n6. When liquid medication is depleted  turn the power switch to the off position.\u003cbr\u003e\nNote: For optimal performance  operate the unit 20 minutes on  and then leave it off for 40 minutes.\u003cbr\u003e\n7. Unplug the power cord from the electrical outlet and tuck it into cord storage cavity.\u003cbr\u003e\n8. Detach the tubing and accessories from the compressor unit.\u003cbr\u003e\n9. Clean and sterilize tubing and accessories\u003cbr\u003e\nCleaning the nebulizer components and accessories\u003cbr\u003e\n1. Disconnect the tubing from the compressor and from the bottom of the nebulizer cup.\u003cbr\u003e\n2. If there is any moisture in the tubing  let the compressor run with the tubing only for 2-3 minutes. The warm air from the compressor will dry out the tubing. Alternatively you can dry the tubing by removing it from the compressor and hanging it up with the end down to allow the moisture or condensation to drain out and evaporate. Use a clean damp cloth to wipe the exterior of the tubing.\u003cbr\u003e\n3. Disassemble tubing and accessories as illustrated.\u003cbr\u003e\n4. Wash all parts with warm water and liquid dish soap. Do not wash the tubing.\u003cbr\u003e\n5. Rinse thoroughly with warm water and shake out water\u003cbr\u003e\n6. Air dry or hand dry nebulizer parts on a clean  lint free cloth. Reassemble nebulizer when parts are dry and store.\u003cbr\u003e\n7. You can also wash the accessories in the top shelf of a dishwasher. Masks cannot be washed safely n a dishwasher. Do not wash the tubing. Place the parts in a dishwasher basket and place the basket on the top rack of the dishwasher. Remove and dry parts when the cycle is complete.\u003cbr\u003e\nDisinfecting and sterilizing nebulizer components and accessories\u003cbr\u003e\n1. Clean the nebulizer components and accessories as described in cleaning section. Every other treatment day  soak the parts in a solution of 1 part distilled white vinegar and 3 parts hot tap water for 1 hour. Do not soak the tubing. You can substitute commercially available respiratory equipment disinfectant for distilled white vinegar by following manufacturers instructions for mixing.\u003cbr\u003e\n2. Rinse all parts thoroughly with warm tap water and dry with a clean  lint-free cloth. Discard vinegar solution when disinfecting is complete.\u003cbr\u003e\nMaintenance\u003cbr\u003e\nAir Filter: The air filter on the top panel of the compressor unit is bright white when new. With use  it will turn grey  which means it is time to replace it.  It must be replaced immediately if gets wet or becomes clogged the air filter last up to 500 hours of use before replacement. A general rule is to replace the air filter whenever the nebulizer unit is replaced.\u003cbr\u003e\nTo replace the air filter  ensure the compressor is turned off  open the air filter cover take out the air filter and replace with a new one. Place the cap back into the socket of the compressor and snap the filter cover back in place.\u003cbr\u003e\nNote: do not attempt to wash and reuse the air filter. Do not use substitute filter material. Compressor damage may result.\u003cbr\u003e\nCleaning the compressor housing: Use a clean  damp cloth to wipe the exterior of the compressor housing.\u003cbr\u003e\nMaintenance and Repair\u003cbr\u003e\nNever operate the nebulizer if it is improperly or incompletely assembled  or damaged. Use only allied genuine parts  accessories  tubing and attachments for the nebulizer.\u003cbr\u003e\nUse of other parts  accessories  tubing and attachments may damage the nebulizer or cause improper function. Do not open or disassemble the compressor unit at any time. This action will void the warranty. Repairs  service and maintenance should be carried out only by an authorized technician. \u003cbr\u003e - INGREDIENTS:See product for details. - MATERIAL\/COMP:Solid (e.g. Chews  Tablet  Toy) - STORAGE\/DISPOSAL REQ:Store in a cool dry place - HEIGHT(INCHES): 8.500 - WIDTH(INCHES):5.750 - LENGTH(INCHES):7.500\n\nBrand: Schuco\n\nManufacturer: \n\nIngredients: See product for details.\n\nDirections: Getting Started\r\n1.\tCheck to ensure the following components of the nebulizer are enclosed:\r\n• Compressor unit\r\n• Tubing and accessories\r\nIf you did not receive the components listed, please contact the dealer where you purchased your nebulizer.\r\n2.\tIt is always a good idea to keep extra tubing and accessories and an extra air filter on hand at all times. You may need them if parts become lost, damaged, or soiled.\r\nSetting up nebulizer compressor and nebulizer accessories\r\n1.\tWash hands with soap and warm water and dry completely with a clean towel.\r\n2.\tPlace the compressor on a clean, dust-free, stable and flat surface. Check the filter monthly or every 10-12 treatments and replace if dirty, clogged, or wet to ensure proper operation.\r\nNote: Tubing and accessories are not sterile from package.\r\n3.\tMake sure tubing and accessories have been cleaned or disinfected before first use and after last daily treatment. Refer to the cleaning and disinfecting tubing and accessories section.\r\n4.\tRemove the nebulizer cap by twisting counter clockwise until it stops and lifts up.\r\n5.\tFill nebulizer cup using eyedropper or syringe with prescribed medication, do not fill more than 8 ml per treatment.\r\n6.\tClose the nebulizer cap and turn clockwise until it is tightened\r\n7.\tIf using the mask press it directly into the nebulizer cap.\r\n8.\tIf using the mouthpiece, attach it firmly into the nebulizer cap. The cap is designed to fit tightly.\r\n9.\tPress one end of the tubing firmly onto to the air outlet on the side of the compressor unit. It is important that the tubing be pushed firmly all the way onto the air outlet of the compressor unit. The tubing is designed to fit tightly.\r\n10.\tFirmly press the other end of the tubing onto the bottom of the nebulizer cup.\r\nOperating the compressor nebulizer\r\n1.\tTake the power cord out of the storage cavity and plug into an electrical outlet.\r\n2.\tLocate the power switch on the front of the unit, and switch it to the “on” position as shown below.\r\n3.\tCheck for moisture leakage near the connections.\r\n4.\tThere are 3 ways to administer medication with this nebulizer (A) Hold the air intake near the nose.(B) If using a mask put the mask on the face. (C) If using a mouthpiece, hold it in the mouth.\r\n5.\tInhale the liquid nebulizer medication\r\n6.\tWhen liquid medication is depleted, turn the power switch to the off position.\r\nNote: For optimal performance, operate the unit 20 minutes on, and then leave it off for 40 minutes.\r\n7.\tUnplug the power cord from the electrical outlet and tuck it into cord storage cavity.\r\n8.\tDetach the tubing and accessories from the compressor unit.\r\n9.\tClean and sterilize tubing and accessories\r\nCleaning the nebulizer components and accessories\r\n1.\tDisconnect the tubing from the compressor and from the bottom of the nebulizer cup.\r\n2.\tIf there is any moisture in the tubing, let the compressor run with the tubing only for 2-3 minutes. The warm air from the compressor will dry out the tubing. Alternatively you can dry the tubing by removing it from the compressor and hanging it up with the end down to allow the moisture or condensation to drain out and evaporate. Use a clean damp cloth to wipe the exterior of the tubing.\r\n3.\tDisassemble tubing and accessories as illustrated.\r\n4.\tWash all parts with warm water and liquid dish soap. Do not wash the tubing.\r\n5.\tRinse thoroughly with warm water and shake out water\r\n6.\tAir dry or hand dry nebulizer parts on a clean, lint free cloth. Reassemble nebulizer when parts are dry and store.\r\n7.\tYou can also wash the accessories in the top shelf of a dishwasher. Masks cannot be washed safely n a dishwasher. Do not wash the tubing. Place the parts in a dishwasher basket and place the basket on the top rack of the dishwasher. Remove and dry parts when the cycle is complete.\r\nDisinfecting and sterilizing nebulizer components and accessories\r\n1.\tClean the nebulizer components and accessories as described in cleaning section. Every other treatment day, soak the parts in a solution of 1 part distilled white vinegar and 3 parts hot tap water for 1 hour. Do not soak the tubing. You can substitute commercially available respiratory equipment disinfectant for distilled white vinegar by following manufacturer’s instructions for mixing.\r\n2.\tRinse all parts thoroughly with warm tap water and dry with a clean, lint-free cloth. Discard vinegar solution when disinfecting is complete.\r\nMaintenance\r\nAir Filter: The air filter on the top panel of the compressor unit is bright white when new. With use, it will turn grey, which means it is time to replace it.  It must be replaced immediately if gets wet or becomes clogged the air filter last up to 500 hours of use before replacement. A general rule is to replace the air filter whenever the nebulizer unit is replaced.\r\nTo replace the air filter, ensure the compressor is turned off, open the air filter cover take out the air filter and replace with a new one. Place the cap back into the socket of the compressor and snap the filter cover back in place.\r\nNote: do not attempt to wash and reuse the air filter. Do not use substitute filter material. Compressor damage may result.\r\nCleaning the compressor housing: Use a clean, damp cloth to wipe the exterior of the compressor housing.\r\nMaintenance and Repair\r\nNever operate the nebulizer if it is improperly or incompletely assembled, or damaged. Use only allied genuine parts, accessories, tubing and attachments for the nebulizer.\r\nUse of other parts, accessories, tubing and attachments may damage the nebulizer or cause improper function. Do not open or disassemble the compressor unit at any time. This action will void the warranty. Repairs, service and maintenance should be carried out only by an authorized technician. \r\n\n\nCautions: Read all warnings before using your nebulizer.\r\nCaution: U.S. Federal Law restricts this device to sale by or on the order of a physician. Use only when prescribed by a physician and with the prescribed medication.\r\nRead all warnings and user’s manual before use. Use the product only for its intended uses as described in the user’s manual. Improper use can result in serious or fatal illness\/injury, improper treatment or property damage.\r\nUse only with nebulizers, tubing and accessories approved for this device. Other compressors and tubing may produce incorrect flow, resulting in improper dosage. Use with other compressors, tubing and accessories should be reviewed with your healthcare professional.\r\nCaution\r\nThis appliance is not for unattended use.\r\nNebulizer compressor safety precautions\r\n1.\tDo not place or store the product where it can fall or be knocked into bathtub, sink, water, or other liquid. Do not place or drop into any liquid. Do not use while bathing.\r\n2.\tDo not reach for a product that has fallen into water or other liquid. Unplug immediately.\r\n3.\tAlways unplug immediately after using.\r\nWarning\r\nTo reduce the risk of serious or fatal injury from electrocution, fire burns and to reduce the risk of damage or malfunction of the unit:\r\n1.\tBefore use, check the serial number label on the bottom of the compressor to ensure that the voltage and current indicated on the unit correspond with the voltage and current available.\r\n2.\tNever operate this product if it:\r\n• Has a damaged cord or plug\r\n• Is not working properly\r\n• Has been dropped or damaged\r\n• Has been exposed to any liquids inside the case.\r\n3.\tKeep all electrical cords away from heated surfaces. Do not overload wall outlets or use extension cords.\r\n4.\tDo not operate where oxygen is being administered in a closed environment such as an oxygen tent.\r\n5.\tNever drop or insert any object into any opening.\r\n6.\tDo not open or disassemble the compressor. Refer all servicing to Allied Health-care Products Inc. authorized service center.\r\n7.\tNever spray liquid onto the compressor housing. Fluid could cause damage to the electrical and compressor parts and could lead to a malfunction. In the event that fluids enter the unit, return the product to allied or an authorized service center for examination and repair.\r\n8.\tDo not use the nebulizer while operating a vehicle\r\n9.\tEMI\/RFI recommendations \r\na.\tDo not turn on or use hand-held personal electronic communication devices such as cellular phones, walkie-talkies and CB radios while the compressor is turned on.\r\nb.\tBe aware of any nearby transmitters (radio, television, microwave, etc.) and avoid operating the compressor close to any of these transmitters.\r\nc.\tTurn off the power if the compressor is not going to be used for any length of time.\r\nd.\tBe aware that adding accessories or components or modifying the compressor may make it more susceptible to EMI\/RFI.\r\nWarning\r\n1.\tTubing and accessories are for single patient use only. Do not share your tubing and accessories with other patients.\r\n2.\tTo reduce the risk of increased bacterial growth, infection, illness or injury from contamination, thoroughly clean and dry all parts of tubing and accessories and thoroughly dry any moisture or condensation in the tubing at the end of every treatment, following the instructions below.\r\n3.\tCleaning the nebulizer unit after each treatment is not enough. The tubing and accessories must also be regularly sterilized and disinfected between treatments to prevent serious or fatal illness caused by contamination.\r\n4.\tNever use tubing with clogged nozzle. If the nozzle is clogged, the aerosol mist will be reduced, altered or stopped, which will diminish or eliminate the effectiveness of the treatment. If clogging occurs, replace with the same model.\r\n5.\tClose supervision is necessary when this product is used by or near children and physically or mentally impaired persons. Never use when sleeping or drowsy.\r\n6.\tThis product contains small parts that may present a choking hazard to small children. The tubing also presents a strangulation hazard.\r\n7.\tChildren under the age of 3 any patient who is unable to use a mouthpiece properly under supervision should use a mask.\r\n8.\tBefore use, check tubing and accessories for proper assembly. All parts should be seated firmly in place. Use of improperly assemble tubing and accessories could diminish or prevent adequate delivery of medication and the effectiveness of the treatment.\r\n\n\nStorage: Store in a cool dry place","brand":"Schuco","offers":[{"title":"Default Title","offer_id":52579944202515,"sku":"010SHU03-5000","price":28.58,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0936\/2853\/0963\/files\/010SHU03-5000-1-HR_ee9ff620-82fb-4b93-9f12-5dbdd4961079.jpg?v=1784631944","url":"https:\/\/shoppetx.com\/products\/rx-schuco-compressor-nebulizer-model-s5000-2","provider":"shoppetx","version":"1.0","type":"link"}